General Purpose Fuses
UL Power Fuses
Class L - Time Delay - A4BQ
arrow bulletBack to UL Power Fuses

PUT THE HIGHEST CURRENT-LIMITATION... AT YOUR SERVICE. Amp-trap® 2000 A4BQ fuses are 20% more current limiting than any other Class L fuse on the market. When correctly coordinated, they bring a superior level of protection to service entrance equipment. Downstream circuit components have maximum protection against short circuit let-thru current. A4BQ's built-in, 4-second time delay characteristic (at 500% of rated current) accommodates harmless inrush currents with no nuisance opening.

Features and Benefits
arrow bulletFastest operation under short circuit conditions: Let-thru currents are typically 20% lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse
arrow bulletTime delay for high inrush loads such as motors and transformers, without nuisance opening
arrow bullet300kA interrupting rating - self-certified, UL witnessed tests
arrow bulletMost current limiting for lowest peak let-thru current; even at fault currents up to 300kA
arrow bulletPure silver links ensure lowest let-thru current and longer fuse life
arrow bulletEasy 2-to-1 selectivity for prevention of nuisance shutdowns and "blackouts"
arrow bulletRejection-style design prevents replacement errors
arrow bulletHigh-visibility orange label gives instant recognition
arrow bulletReduced inventory because A4BQ can replace all older types of Class L fuses now in service
arrow bulletMetal®mbossed date and catalog number for traceability and lasting identification
arrow bulletFiberglass body provides dimensional stability in harsh industrial settings
arrow bulletHigh®rade silica filler ensures fast arc quenching

Applications
arrow bulletMains, Feeders
arrow bulletLarge Motors
arrow bulletLighting, Heating & General Loads
arrow bulletCircuit Breaker Back-up
arrow bulletDC Rated: UPS DC Links, Battery Disconnects, Other DC Applications



arrow bulletReturn to product information
 
DXF Drawings
arrow bulletA4BQ100  PDF: A4BQ(100-600).pdf
arrow bulletA4BQ100-TA  PDF: A4BQ(100-600)TA.pdf
arrow bulletA4BQ1000  DXF: A4BQ(1000-1200).dxf  PDF: A4BQ(1000-1200).pdf
arrow bulletA4BQ1000-TA  PDF: A4BQ(801-1200)-TA.pdf
arrow bulletA4BQ1200  DXF: A4BQ(1000-1200).dxf  PDF: A4BQ(1000-1200).pdf
arrow bulletA4BQ1200-TA  PDF: A4BQ(801-1200)-TA.pdf
arrow bulletA4BQ1350  PDF: A4BQ1600.pdf
arrow bulletA4BQ1350-TA (Not online currently)
arrow bulletA4BQ1400  PDF: A4BQ1600.pdf
arrow bulletA4BQ1400-TA (Not online currently)
arrow bulletA4BQ150  PDF: A4BQ(100-600).pdf
arrow bulletA4BQ150-TA  PDF: A4BQ(100-600)TA.pdf
arrow bulletA4BQ1500  PDF: A4BQ1600.pdf
arrow bulletA4BQ1500-TA (Not online currently)
arrow bulletA4BQ1600  PDF: A4BQ1600.pdf
arrow bulletA4BQ1600-TA (Not online currently)
arrow bulletA4BQ1800  PDF: A4BQ2000.pdf
arrow bulletA4BQ1800-TA  PDF: A4BQ(1601-2000)-TA.pdf
arrow bulletA4BQ1800-TA  DXF: A4BQ2000-TA.dxf
arrow bulletA4BQ1900  PDF: A4BQ2000.pdf
arrow bulletA4BQ200  PDF: A4BQ(100-600).pdf
arrow bulletA4BQ200-TA  PDF: A4BQ(100-600)TA.pdf
arrow bulletA4BQ2000  PDF: A4BQ2000.pdf
arrow bulletA4BQ2000-TA  PDF: A4BQ(1601-2000)-TA.pdf
arrow bulletA4BQ2000-TA  DXF: A4BQ2000-TA.dxf
arrow bulletA4BQ2001-TA  PDF: A4BQ(2001-2500)-TA.pdf
arrow bulletA4BQ2200-TA  PDF: A4BQ(2001-2500)-TA.pdf
arrow bulletA4BQ250  PDF: A4BQ(100-600).pdf
arrow bulletA4BQ250-TA  PDF: A4BQ(100-600)TA.pdf
arrow bulletA4BQ2500  PDF: A4BQ2500.pdf
arrow bulletA4BQ2500-TA  PDF: A4BQ(2001-2500)-TA.pdf
arrow bulletA4BQ2501  PDF: A4BQ3000.pdf
arrow bulletA4BQ300  PDF: A4BQ(100-600).pdf
arrow bulletA4BQ300-TA  PDF: A4BQ(100-600)TA.pdf
arrow bulletA4BQ3000  PDF: A4BQ3000.pdf
arrow bulletA4BQ3000-TA  PDF: A4BQ(2501-3000)-TA.pdf
arrow bulletA4BQ350  PDF: A4BQ(100-600).pdf
arrow bulletA4BQ350-TA  PDF: A4BQ(100-600)TA.pdf
arrow bulletA4BQ3500  PDF: A4BQ4000.pdf
arrow bulletA4BQ3500-TA  PDF: A4BQ(3001-4000)-TA.pdf
arrow bulletA4BQ3800  PDF: A4BQ4000.pdf
arrow bulletA4BQ3800-TA  PDF: A4BQ(3001-4000)-TA.pdf
arrow bulletA4BQ400  PDF: A4BQ(100-600).pdf
arrow bulletA4BQ400-TA  PDF: A4BQ(100-600)TA.pdf
arrow bulletA4BQ4000  PDF: A4BQ4000.pdf
arrow bulletA4BQ4000-TA  PDF: A4BQ(3001-4000)-TA.pdf
arrow bulletA4BQ450  PDF: A4BQ(100-600).pdf
arrow bulletA4BQ450-TA  PDF: A4BQ(100-600)TA.pdf
arrow bulletA4BQ500  PDF: A4BQ(100-600).pdf
arrow bulletA4BQ500-TA  PDF: A4BQ(100-600)TA.pdf
arrow bulletA4BQ5000  PDF: A4BQ5000.pdf
arrow bulletA4BQ5000-TA (Not online currently)
arrow bulletA4BQ600  PDF: A4BQ(100-600).pdf
arrow bulletA4BQ600-TA  PDF: A4BQ(100-600)TA.pdf
arrow bulletA4BQ6000  PDF: A4BQ6000.pdf
arrow bulletA4BQ6000-TA  PDF: A4BQ(5001-6000)-TA.pdf
arrow bulletA4BQ601  DXF: A4BQ800.dxf  PDF: A4BQ800.pdf
arrow bulletA4BQ601-TA  PDF: A4BQ(601-800)-TA.pdf
arrow bulletA4BQ650  DXF: A4BQ800.dxf  PDF: A4BQ800.pdf
arrow bulletA4BQ650-TA  PDF: A4BQ(601-800)-TA.pdf
arrow bulletA4BQ700  DXF: A4BQ800.dxf  PDF: A4BQ800.pdf
arrow bulletA4BQ700-TA  PDF: A4BQ(601-800)-TA.pdf
arrow bulletA4BQ750  DXF: A4BQ800.dxf  PDF: A4BQ800.pdf
arrow bulletA4BQ750-TA  PDF: A4BQ(601-800)-TA.pdf
arrow bulletA4BQ800  DXF: A4BQ800.dxf  PDF: A4BQ800.pdf
arrow bulletA4BQ800-TA  PDF: A4BQ(601-800)-TA.pdf
arrow bulletA4BQ900-TA  PDF: A4BQ(801-1200)-TA.pdf
 
UL File Card
JDDZ.E2137 (Link to UL website)
 
CSA File Card
1422-02 012636_0_000 (Link to CSA website)
 
Literature
 
Training
  • Amp-Trap 2000® No-Damage Protection System (Download)


Have a Question?

arrow bulletRequest a sample
arrow bulletRequest a quote
arrow bulletLocate a distributor
arrow bulletE-mail technical services
arrow bulletTell a colleague about this product
arrow bulletKeep me informed about this product
spacer


spacer
spacer
spacer spacer
RATINGS

arrow bullet
AC: 600VAC, 200kA I.R. (100 - 6000A)

NOTE
100 - 600A Ratings are Now UL Listed!



arrow bullet
DC: 500VDC, 100kA I.R. (601 to 3000A)


spacer
spacer
APPROVALS

arrow bulletUL Listed to Standard 248-10 (601-6000A)
arrow bulletUL Listed to Standard 248-8 (100-600A)
arrow bulletDC Listed to UL Standard 248
arrow bulletCSA Certified to Standard C22.2 No.248.10
arrow bulletIEC 269-2-1
arrow bulletSome Ratings RoHS Compliant